Parking Deck/Lot PVC Jacketed MC Cable

Galvanized Steel Armor with PVC Jacket

Features & Benefits

  • Galvanized steel armor with PVC jacket
  • UL® listed for direct burial in earth or concrete encasement
  • Listed for –40°C low temperature use
  • UL®1569, 70,000 BTU and FT4 vertical tray flame listed
  • Sunlight and oil resistant with direct plow-in capability
  • Made in USA of US and/or imported materials

Applications

Branch circuit and feeder wiring for lighting, control and signal circuits in wet, dirty or oily locations, buried directly in earth or concrete, surface mounted or trenched for use in parking deck or parking lot applications, golf courses, ski mountains, docks, marinas, pumping stations and stadium lighting. Also used in continuous runs to outdoor or underground swimming pool motors, pumps and related equipment (per NEC® 680), fished, exposed or concealed cable trays, direct sunlight and hazardous locations up to Class I & II, Div. 2 and Class III, Div. 1 & 2 (NEC® Articles 501, 502, 503, 530).Galvanized Steel Armor with PVC Jacket

parking-lot-cable-technical-drawing

Description

Armor & Jacket
Galvanized Interlocking Steel Strip with gray PVC jacket. Other jacket colors available by special order
Conductors
Solid/Stranded Copper
Conductor Insulation
THHN/THWN
Assembly Covering
Polypropylene Tape
Maximum Temperature Rating
90°C (dry);
75°C (wet)
Grounding
Conductor
Insulated Green Copper
Grounding
Neutral Conductor White for 120/208V circuits
Grey for 480Y/277V circuits
Maximum Voltage
600V

References & Ratings

  • UL® 83, 1479, 1569, 1581, 2556, File Reference E80042
  • NEC® 230.43, 300.5, 392, 396.10(A), 330, 501, 502, 503, 530, 504, 505, 511.7, 513.7(A), 514.7, 515.7(A), 516.7(A), 680.21(A)
  • Federal Specification A-A–59544 (formerly J-C–30B)
  • UL® listed for –40°C low temperature
  • UL® 1569 70,000 BTU and FT 4/ Vertical Tray Flame Tests IEEE 1202
  • UL® listed for Cable Tray use
  • UL® listed for Direct Burial including Concrete Encasement & wet locations
  • UL® listed Sunlight Resistant
  • UL® listed Oil Resistant II
  • Hazardous locations up to Class I & II, Div. 2 and Class III, Div. 1 & 2 (NEC® Articles 501, 502, 503, 530)
  • Cable tray rated, install per NEC®
  • Wet locations per NEC® 330.10(11)(C)
  • Made in USA of US and/or imported materials
Product Code Stock Items CoilProduct Code Stock Items ReelTrade SizeGrounding Conductor AWGLength (feet) CoilLength (feet) ReelApprox. Weight/1000 Feet (lbs.)Armor/Jacket MinimumO.D. (inches)
120/208V
2304-42-002304-60-0012-2 Solid (black, white)12 (solid green)250'1000'2800.495/0.605
2305-42-002305-60-0012-3 Solid (black, red, white)12 (solid green)250'1000'3200.530/0.640
2306-42-002306-60-0012-4 Solid (black, blue, red, white)12 (solid green)250'1000'3700.565/0.675
2307-42-002307-60-0010-2 Solid (black, white)10 (solid green)250'1000'3550.560/0.670
2308-42-002308-60-0010-3 Solid (black, red, white)10 (solid green)250'1000'4150.600/0.710
2309-42-002309-60-0010-4 Solid (black, blue, red, white)10 (solid green)250'1000'4800.645/0.755
2316-99-002316-99-008-3 Stranded (black, red, white)††10 (stranded green)5600.685/0.795
2320-99-002320-99-006-3 Stranded (black, red, white)††8 (stranded green)8050.855/0.965
480Y/277 Volt
2304-42-012304-60-0112-2 Solid (brown)12 (solid green)250'1000'2800.495/0.605
2305-42-012305-60-0112-3 Solid (brown, orange)12 (solid green)250'1000'3200.530/0.640
2306-42-012306-60-0112-4 Solid (brown, orange, yellow)12 (solid green)250'1000'3700.565/0.675
2307-42-012307-60-0110-2 Solid (brown)10 (solid green)250'1000'3550.560/0.670
2308-42-012308-60-0110-3 Solid (brown, orange)10 (solid green)250'1000'4150.600/0.710
2309-42-012309-60-0110-4 Solid (brown, orange, yellow)10 (solid green)250'1000'4800.645/0.755
Note: All dimensions and weights subject to normal manufacturing tolerances. Non-stock items require lead time and minimum quantity order.